Riselink Mini OTDR - NK3200D, NK3200F1 or NK3200F2
- Fiber type
- G.652 single-mode.
- Functions
- OTDR, event mapping, optical power meter, visual fault locator and stable light source.
- Additional functions
- RJ45 cable sequence and length checks, cable tracing and LED light. Manufacturer-listed RJ45 length range: 300 m.
- Display
- 3.5-inch color LCD with physical navigation and function keys.
- OPM wavelength range
- 800-1700 nm. Measurement range: -50 to +26 dBm. Manufacturer-listed uncertainty: +/-5%.
- OPM calibrated wavelengths
- 850, 980, 1300, 1310, 1490, 1550, 1625 and 1650 nm. Interface compatibility: FC/SC/ST.
- OPM signal identification
- CW, 270 Hz, 330 Hz, 1 kHz and 2 kHz.
- VFL wavelength
- 650 nm +/-20 nm. Manufacturer-listed output: at least 10 mW. Modes: CW, 1 Hz and 2 Hz. Interface compatibility: FC/SC/ST.
- Stable light source
- FP-LD; manufacturer-listed output at least -5 dBm; modulation at 270 Hz, 330 Hz, 1 kHz and 2 kHz. CW stability: +/-0.5 dB over 15 minutes, tested after 15 minutes of preheating.
- Data interface
- Micro USB. External storage interface: TF card.
- Battery
- rechargeable lithium-polymer, 3.7 V, 4000 mAh. Power adapter output: 5 V DC, 2 A.
- Housing dimensions
- 173 x 82 x 37 mm. Instrument weight: up to 350 g.
- Operating temperature
- -10 to +50 C. Storage temperature: -40 to +70 C. Relative humidity: 0-95%, non-condensing.
- Specification
- The following additional OTDR specifications are documented for NK3200D in the supplied manufacturer brochure; they are not automatically assigned to F1 or F2.
- OTDR connector
- FC/UPC, with interchangeable SC/ST interfaces. Interface compatibility does not mean every adapter is included.
- Selectable OTDR range
- 500 m to 60 km. This is a range setting, not a guaranteed measurement distance.
- Pulse width
- 3 ns to 10 us. Dynamic-range test notes specify maximum pulse width and averaging for more than 3 minutes.
- Typical event dead zone
- 3 m, at minimum range and minimum pulse width, with fiber-end reflection loss greater than 45 dB.
- Distance accuracy
- +/-(1 m + sampling interval + 0.005% of test distance). Sampling interval: 0.05 m to 8 m; sampling points: 16k to 128k.
- File format
- standard SOR. Internal storage: at least 600 records; external storage interface: TF card.